Laser scanning confocal microscope (LSCM) is one of the most important tools for biological imaging due to its strong optical sectioning capability, high signal-to-noise ratio, and high resolution. On the basis of LSCM, line-scanning fluorescence microscopy (LSFM) uses linear scanning instead of point scanning to improve the speed of image acquisition. It has the advantages of simple system structure, fast imaging speed, and weak phototoxicity, and in addition, it is more suitable for high-resolution and fast imaging of living thick samples. It is of great significance for studying the life science, biomedicine, and others. However, the current LSFM technology still faces many urgent problems in terms of system flexibility, imaging speed, resolution and optical sectioning capabilities. Therefore, based on the existing multifocal structured illumination microscopy (MSIM) in our laboratory, a digital line-scanning fluorescence microscopy (DLSFM) based on digital micromirror device(DMD) is presented in this paper. In the illumination path, a high-speed spatial light modulator DMD is adopted to realize multi-line parallel scanning excitation, which simplies the optical system and improves the flexibility and scanning speed of the system. A DLSFM image reconstruction algorithm based on the standard deviation of fluorescence signal is proposed, which is combined withthree-dimensional (3D) Landweber deconvolution algorithm to achieve 3D high-resolution optical slice image reconstruction. On this basis, the imaging experiments on fluorescent beads and standard samples of mouse kidney section are carried out by using DLSFM. The experimental results show that the resolution of DLSFM in the x, y and z directions is 1.33 times, 1.42 times and 1.19 times that of wide field microscope, respectively, and the fast 3D high-resolution optical sectioning imaging of biological samples is realized, which lays a technical foundation for further developing the rapid high-resolution imaging of the whole cells and tissues in vivo.
[1] Minsky M 1988 Scanning 10 128Google Scholar
[2] Mitsuhiro I, Hiromi S 1998 SPIE 34 68
[3] Gustafsson M G 2010 J. Microsc. 198 82
[4] 赵启韬, 苗俊英 2003 北京生物医学工程 22 52Google Scholar
Zhao Q T, Miao J Y 2003 Beijing Biomed. Eng. 22 52Google Scholar
[5] Rainer H, Christoph G C 1999 SPIE 35 185
[6] Sauermann K, Gambichler T, Wilmert M 2002 Skin Res.Technol. 8 141Google Scholar
[7] Taejoong K, DaeGab G, Jun-Hee L 2009 Meas. Sci. Technol. 20 055501Google Scholar
[8] SchulzO, Pieper C, Clever M, et al. 2013 Proc. Natl. Acad. Sci. U.S.A. 110 21000Google Scholar
[9] Fan G Y, Fujisaki H, Miywwaki A, Tsay R K, Tsien R Y, Ellisman M H 1999 Biophys. J. 76 2412Google Scholar
[10] Rahadhyaksha M, Anderson R R, Webb R H 1999 Appl. Opt. 38 2105Google Scholar
[11] Li Y X, Gautam V, Brüstle A, Cockburn I A, Daria VR, Gillespie C, Gaus K, Alt C, Lee W M 2017 J. Bophotonics 10 1526Google Scholar
[12] Sheppard C JR, Mao X Q 1988 J. Mod. Optic. 35 1169Google Scholar
[13] Puash W C, Wasser M 2016 Methods 96 103Google Scholar
[14] Yazawa M, Hsueh B, Jia X, Pasca A M, Bernstein J A, Hallmayer J, Dolmetsch R E 2011 Nature 471 230Google Scholar
[15] Reto F, Andreas S, Yury B 2007 Histochem. Cell Biol. 128 499Google Scholar
[16] Kang B I, Sumin H, Hwajoon P, Dongsun K, Beop M K 2005 Opt. Express 13 5151Google Scholar
[17] Ondrej M, Martin K, Kai Wicker, Gerhard K, Ingo K, Rainer H 2012 Opt. Express 20 24167Google Scholar
[18] Lu R W, Wang B Q, Zhang QX, Yao XC 2013 Biomed.Opt. Express 4 1673Google Scholar
[19] Wang B, Lu R, Zhang Q, Yao X 2013 Quant. Imag. Med. Surg. 3 243
[20] Yanan Z, Lu R W, Wang B Q, Zhang Q X, Yao X C 2015 Opt. Lett. 40 1683
[21] Poher V, Zhang HX, Kennedy GT 2007 Opt. Express 15 11196Google Scholar
[22] Chamma I, Levet F, Sibarita J B, Sainlos M, Thoumine O 2016 Neurophotonics 3 041810Google Scholar
[23] Endesfelder U, Heilemann M 2014 Nat. Methods 11 235Google Scholar
[24] Flors C 2011 Biopolymers 95 290Google Scholar
[25] Patterson G, Davidson M, Manley S 2010 Annu. Rev. Phys. Chem. 61 345Google Scholar
[26] Hossain S, Hashimoto M, Katakura M, Mamun A A, Shido O 2015 Bmc. Complem. Altern. M 15 1
[27] Rainer H, Pier A, Benedetti 2006 Appl. Opt. 45 5037Google Scholar
[28] Ren Y X, Lu R D, Gong L 2015 Ann. Phys.(Berlin) 527 447Google Scholar
[29] 冯维, 张福民, 王惟婧, 曲兴华 2017 66 234201Google Scholar
Feng W, Zhang F M, Wang W J, Qu X H 2017 Acta Phys. Sin. 66 234201Google Scholar
[30] Vienola K V, Damodaran M, Braaf B, Vermeer K A, Johannes F 2015 Opt. Lett. 40 5335Google Scholar
[31] Wu J J, Li S W, Cao H Q, Lin D Y, Yu B, Qu J L 2018 Opt. Express 26 31430Google Scholar
[32] Vonesch C, Unser M 2008 IEEE Trans. Image Process. 17 539
[33] Zhang W, Yu B, Lin D Y, Yu H H, Li S W, Qu J L 2020 Opt. Express 28 10919Google Scholar
-
图 2 DMD不同填充因子的数字线扫描成像分析 (a)不同密度线条纹激发下的罗丹明荧光溶液图像; (b) 不同帧的同扫描线位置的强度轮廓线
Figure 2. Digital line scan imaging analysis of DMD with different fill factor: (a) The rhodamine fluorescence solution images excited by different density scanning lines; (b) the intensity profiles through the dotted line in (a).
图 3 DMD不同填充因子的信噪比分析 (a) 焦面信号和背景信号强度分布图; (b) 焦面信号和背景信号强度与DMD填充因子的关系曲线; (c) DMD不同填充因子的信噪比曲线
Figure 3. SNR analysis of DMD with different fill factor: (a) The intensity distributions of focal plane signal and background signal intensity; (b) the intensity curves of focal planne signal (black) and background signal (red); (c) the curve of the SNR versus fill factor of DMD.
图 4 100 nm荧光珠标定的系统三维空间分辨率 (a)宽场图像; (b)虚拟狭缝重构图像; (c)标准差重构图像; (d)虚拟狭缝与LW解卷积组合重构图像; (e)标准差与LW解卷积组合重构图像. 其右边对应的直方图为25颗荧光珠在沿
$x, y, z$ 方向的FWHM分布,$\overline X, \overline Y, \overline Z $ 分别为其平均值Figure 4. 3D spatial resolution of the system calibrated by the 100 nm fluorescent bead: (a) WF image; (b) VS image; (c) STD image; (d) VS + DE image; (e) STD + DE image. The corresponding histograms on the right show the measured distribution of
$x, y, z$ FWHM values from 25 beads.图 6 不同算法的图像重构细节比较 (a)−(c) 分别为WF图像、VS图像和STD图像; (d)−(f) 分别由(a)−(c)经Landweber DE算法处理成像; (i)−(n) 分别为图(a)−(f)黄色线框区域的放大图
Figure 6. Comparison of image reconstruction details of different algorithms: (a)−(f) WF image, VS image, and STD image; (d)−(f) the Landweber DE images for (a)−(c); (i)−(n) magnified view of the yellow rectangular areas in (a)−(f).
图 7 不同算法重构图像的对比度比较 (a)−(c) 分别为WF图像、VS图像和STD图像; (d)−(f) 分别为图(a)−(c)经Landwebe解卷积算法处理成像; (g)−(h) 分别为图(a)−(f)白色虚线位置的归一化强度轮廓图
Figure 7. Contrast comparison of reconstructed images with different algorithms: (a)−(c) WF image, VS image, and STD image; (d)−(f) images obtained from (a)−(c) processed by Landwebe deconvolution algorithm; (g)−(h) the normalized intensity profiles through the white dotted line position in (a)−(f).
-
[1] Minsky M 1988 Scanning 10 128Google Scholar
[2] Mitsuhiro I, Hiromi S 1998 SPIE 34 68
[3] Gustafsson M G 2010 J. Microsc. 198 82
[4] 赵启韬, 苗俊英 2003 北京生物医学工程 22 52Google Scholar
Zhao Q T, Miao J Y 2003 Beijing Biomed. Eng. 22 52Google Scholar
[5] Rainer H, Christoph G C 1999 SPIE 35 185
[6] Sauermann K, Gambichler T, Wilmert M 2002 Skin Res.Technol. 8 141Google Scholar
[7] Taejoong K, DaeGab G, Jun-Hee L 2009 Meas. Sci. Technol. 20 055501Google Scholar
[8] SchulzO, Pieper C, Clever M, et al. 2013 Proc. Natl. Acad. Sci. U.S.A. 110 21000Google Scholar
[9] Fan G Y, Fujisaki H, Miywwaki A, Tsay R K, Tsien R Y, Ellisman M H 1999 Biophys. J. 76 2412Google Scholar
[10] Rahadhyaksha M, Anderson R R, Webb R H 1999 Appl. Opt. 38 2105Google Scholar
[11] Li Y X, Gautam V, Brüstle A, Cockburn I A, Daria VR, Gillespie C, Gaus K, Alt C, Lee W M 2017 J. Bophotonics 10 1526Google Scholar
[12] Sheppard C JR, Mao X Q 1988 J. Mod. Optic. 35 1169Google Scholar
[13] Puash W C, Wasser M 2016 Methods 96 103Google Scholar
[14] Yazawa M, Hsueh B, Jia X, Pasca A M, Bernstein J A, Hallmayer J, Dolmetsch R E 2011 Nature 471 230Google Scholar
[15] Reto F, Andreas S, Yury B 2007 Histochem. Cell Biol. 128 499Google Scholar
[16] Kang B I, Sumin H, Hwajoon P, Dongsun K, Beop M K 2005 Opt. Express 13 5151Google Scholar
[17] Ondrej M, Martin K, Kai Wicker, Gerhard K, Ingo K, Rainer H 2012 Opt. Express 20 24167Google Scholar
[18] Lu R W, Wang B Q, Zhang QX, Yao XC 2013 Biomed.Opt. Express 4 1673Google Scholar
[19] Wang B, Lu R, Zhang Q, Yao X 2013 Quant. Imag. Med. Surg. 3 243
[20] Yanan Z, Lu R W, Wang B Q, Zhang Q X, Yao X C 2015 Opt. Lett. 40 1683
[21] Poher V, Zhang HX, Kennedy GT 2007 Opt. Express 15 11196Google Scholar
[22] Chamma I, Levet F, Sibarita J B, Sainlos M, Thoumine O 2016 Neurophotonics 3 041810Google Scholar
[23] Endesfelder U, Heilemann M 2014 Nat. Methods 11 235Google Scholar
[24] Flors C 2011 Biopolymers 95 290Google Scholar
[25] Patterson G, Davidson M, Manley S 2010 Annu. Rev. Phys. Chem. 61 345Google Scholar
[26] Hossain S, Hashimoto M, Katakura M, Mamun A A, Shido O 2015 Bmc. Complem. Altern. M 15 1
[27] Rainer H, Pier A, Benedetti 2006 Appl. Opt. 45 5037Google Scholar
[28] Ren Y X, Lu R D, Gong L 2015 Ann. Phys.(Berlin) 527 447Google Scholar
[29] 冯维, 张福民, 王惟婧, 曲兴华 2017 66 234201Google Scholar
Feng W, Zhang F M, Wang W J, Qu X H 2017 Acta Phys. Sin. 66 234201Google Scholar
[30] Vienola K V, Damodaran M, Braaf B, Vermeer K A, Johannes F 2015 Opt. Lett. 40 5335Google Scholar
[31] Wu J J, Li S W, Cao H Q, Lin D Y, Yu B, Qu J L 2018 Opt. Express 26 31430Google Scholar
[32] Vonesch C, Unser M 2008 IEEE Trans. Image Process. 17 539
[33] Zhang W, Yu B, Lin D Y, Yu H H, Li S W, Qu J L 2020 Opt. Express 28 10919Google Scholar
Catalog
Metrics
- Abstract views: 7650
- PDF Downloads: 169
- Cited By: 0