In a swept source-optical coherence tomography system, the telecentric scanning mode gives rise to central saturation artifacts,partial structural loss, and low SNR (signal-to-noise ratio) area in the corneal image, which affects the accuracy of corneal contour extraction. In order to solve this problem, in this paper we propose an automatic extraction algorithm for corneal image of low quality. This algorithm divides the image into high and low SNR region according to the standard deviation distribution of the cornea image. For the high SNR region, we localize the peak point to extract the contour. For the low SNR region, image enhancement is achieved by the registration and superposition of successive frames, which provides reference contour points for low SNR areas. Then corneal contour localization is achieved by weighing the advantages and disadvantages of reference contour points and local line fitting results. Finally, global polynomial fitting is used to achieve the whole corneal contour information. Experiments on the optical eye model show that comparing with the existing algorithms, the accuracy of corneal contour extraction is improved by 4.9% on average.
-
Keywords:
- optical coherence tomography /
- swept-source optical coherence tomography /
- cornea /
- contour extraction
[1] Wang J F, Zheng W, Lin K, Huang Z W 2016 Opt. Lett. 41 3045
Google Scholar
[2] Kumar A, Baumann B, Hafner J, Ginner L, Augustin M, Salas M, Pircher M, Leitgeb R, Prager S, Schmidterfurth U 2016 Biomed. Opt. Express 8 207
[3] Grulkowski I, Liu J J, Potsaid B, Jayaraman V, Jiang J, Fujimoto J G, Cable A E 2013 Opt. Lett. 38 673
Google Scholar
[4] Polans J, Cunefare D, Cole E, Keller B, Mettu P S, Cousins S W, Allingham M J, Izatt J A, Farsiu S 2017 Opt. Lett. 42 17
Google Scholar
[5] Camino A, Jia Y L, Liu G J, Wang J, Huang D 2017 Biomed. Opt. Express 8 3053
Google Scholar
[6] Kaluzny B J, Karnowski K, Szkulmowski M, Wojtkowski M, Gora M 2011 Biomed. Opt. Express 2 2709
Google Scholar
[7] Lawman S, Dong Y, Williams B M, Romano V, Kaye S, Harding S P, Willoughby C, Shen Y C, Zheng Y L 2016 Opt. Express 24 12395
Google Scholar
[8] Lawman S, Madden P W, Vito R, Romano V, Dong Y, Mason S, Williams B M, Kaye S B, Willoughby C E, Harding S P, Shen Y C 2017 Biomed. Opt. Express 8 5579
Google Scholar
[9] Wang L L, Xiong Q Z, Ge X, Bo E, Xie J, Liu X Y, Yu X J, Wang X H, Wang N S, Chen S, Wu X, Liu L B 2019 Opt. Express 27 1298
Google Scholar
[10] Williams D, Zheng Y L, Bao F J, Elsheikh A 2013 J. Biomed. Opt. 18 056003
[11] Li Y, Shekhar R, Huang D 2002 Proc. SPIE 4684 167
Google Scholar
[12] Li Y, Shekhar R, Huang D 2006 Ophthalmology 113 792
Google Scholar
[13] Shu P, Sun Y 2012 J. Innov. Opt. Heal. Sci. 5 9
[14] LaRocca F, Chiu S J, McNabb R P, Kuo A N, Izatt J A, Farsiu S 2011 Biomed. Opt. Express 2 1524
Google Scholar
[15] Keller B, Draelos M, Tang G, Farsiu S, Kuo A N, Hauser K, Izatt J A 2018 Biomed. Opt. Express 9 2716
Google Scholar
[16] Santos V A, Schmetterer L, Stegmann H, Pfister M, Messner A, Schmidinger G, Garhofer G, Werkmeister R M 2019 Biomed. Opt. Express 10 622
Google Scholar
[17] Otsu N 2007 IEEE. Trans. Syst. Man. Cybern. 9 62
[18] Doughty M J, Zaman M L 2000 Surv. Ophthalmol. 44 367
Google Scholar
[19] Gifford P, Ahmed A, Swarbrick H A 2011 Invest. Ophth. Vis. Sci. 52 3648
Google Scholar
[20] Atchison D A, Jones C E, Schmid K L, Nicola P, Pope J M, Strugnell W E, Riley R A 2004 Invest. Ophth. Vis. Sci. 45 3380
Google Scholar
[21] Wang Q, Liu W W, Wu Y L, Ma Y, Zhao G Q 2017 Clin. Exp. Optom. 100 250
[22] Saenzfrances F, Gonzalezpastor E, Borregosanz L, Jerezfidalgo M, Martinezdelacasa J, Mendezhernandez C, Santosbueso E, Fernandezvidal A, Garciasanchez J, Garciafeijoo J 2012 J. FR. Ophtalmol. 35 333
Google Scholar
[23] Read S A, Collins M J 2009 Optometry & Vision Science Official Publication of the American Academy of Optometry 86 170
[24] Zaki F, Wang Y H, Su H, Yuan X, Liu X 2017 Biomed. Opt. Express 8 2720
Google Scholar
[25] 张强, 那彦, 李建军 2006 应用光学 27 4
Zhang Q, Na Y, Li J J 2006 J. Appl. Opt. 27 4
-
表 1 两种算法对角膜轮廓平均提取精度对比
Table 1. Comparison of the accuracy of two algorithmsfor contour extraction of high and low SNR regions.
评价指标 文献[14] 本文算法 精度提高值/% 平均误差值/pixels 2.8 0.9 4.9 偏差率/% 7.2 2.3 -
[1] Wang J F, Zheng W, Lin K, Huang Z W 2016 Opt. Lett. 41 3045
Google Scholar
[2] Kumar A, Baumann B, Hafner J, Ginner L, Augustin M, Salas M, Pircher M, Leitgeb R, Prager S, Schmidterfurth U 2016 Biomed. Opt. Express 8 207
[3] Grulkowski I, Liu J J, Potsaid B, Jayaraman V, Jiang J, Fujimoto J G, Cable A E 2013 Opt. Lett. 38 673
Google Scholar
[4] Polans J, Cunefare D, Cole E, Keller B, Mettu P S, Cousins S W, Allingham M J, Izatt J A, Farsiu S 2017 Opt. Lett. 42 17
Google Scholar
[5] Camino A, Jia Y L, Liu G J, Wang J, Huang D 2017 Biomed. Opt. Express 8 3053
Google Scholar
[6] Kaluzny B J, Karnowski K, Szkulmowski M, Wojtkowski M, Gora M 2011 Biomed. Opt. Express 2 2709
Google Scholar
[7] Lawman S, Dong Y, Williams B M, Romano V, Kaye S, Harding S P, Willoughby C, Shen Y C, Zheng Y L 2016 Opt. Express 24 12395
Google Scholar
[8] Lawman S, Madden P W, Vito R, Romano V, Dong Y, Mason S, Williams B M, Kaye S B, Willoughby C E, Harding S P, Shen Y C 2017 Biomed. Opt. Express 8 5579
Google Scholar
[9] Wang L L, Xiong Q Z, Ge X, Bo E, Xie J, Liu X Y, Yu X J, Wang X H, Wang N S, Chen S, Wu X, Liu L B 2019 Opt. Express 27 1298
Google Scholar
[10] Williams D, Zheng Y L, Bao F J, Elsheikh A 2013 J. Biomed. Opt. 18 056003
[11] Li Y, Shekhar R, Huang D 2002 Proc. SPIE 4684 167
Google Scholar
[12] Li Y, Shekhar R, Huang D 2006 Ophthalmology 113 792
Google Scholar
[13] Shu P, Sun Y 2012 J. Innov. Opt. Heal. Sci. 5 9
[14] LaRocca F, Chiu S J, McNabb R P, Kuo A N, Izatt J A, Farsiu S 2011 Biomed. Opt. Express 2 1524
Google Scholar
[15] Keller B, Draelos M, Tang G, Farsiu S, Kuo A N, Hauser K, Izatt J A 2018 Biomed. Opt. Express 9 2716
Google Scholar
[16] Santos V A, Schmetterer L, Stegmann H, Pfister M, Messner A, Schmidinger G, Garhofer G, Werkmeister R M 2019 Biomed. Opt. Express 10 622
Google Scholar
[17] Otsu N 2007 IEEE. Trans. Syst. Man. Cybern. 9 62
[18] Doughty M J, Zaman M L 2000 Surv. Ophthalmol. 44 367
Google Scholar
[19] Gifford P, Ahmed A, Swarbrick H A 2011 Invest. Ophth. Vis. Sci. 52 3648
Google Scholar
[20] Atchison D A, Jones C E, Schmid K L, Nicola P, Pope J M, Strugnell W E, Riley R A 2004 Invest. Ophth. Vis. Sci. 45 3380
Google Scholar
[21] Wang Q, Liu W W, Wu Y L, Ma Y, Zhao G Q 2017 Clin. Exp. Optom. 100 250
[22] Saenzfrances F, Gonzalezpastor E, Borregosanz L, Jerezfidalgo M, Martinezdelacasa J, Mendezhernandez C, Santosbueso E, Fernandezvidal A, Garciasanchez J, Garciafeijoo J 2012 J. FR. Ophtalmol. 35 333
Google Scholar
[23] Read S A, Collins M J 2009 Optometry & Vision Science Official Publication of the American Academy of Optometry 86 170
[24] Zaki F, Wang Y H, Su H, Yuan X, Liu X 2017 Biomed. Opt. Express 8 2720
Google Scholar
[25] 张强, 那彦, 李建军 2006 应用光学 27 4
Zhang Q, Na Y, Li J J 2006 J. Appl. Opt. 27 4
Catalog
Metrics
- Abstract views: 7999
- PDF Downloads: 65
- Cited By: 0