Search

Article

x

留言板

尊敬的读者、作者、审稿人, 关于本刊的投稿、审稿、编辑和出版的任何问题, 您可以本页添加留言。我们将尽快给您答复。谢谢您的支持!

姓名
邮箱
手机号码
标题
留言内容
验证码

Application of amplitude and phase registration in blood flow imaging using optical coherence tomography

Liu Guo-Zhong Zhou Zhe-Hai Qiu Jun Wang Xiao-Fei Liu Gui-Li Wang Rui-Kang

Citation:

Application of amplitude and phase registration in blood flow imaging using optical coherence tomography

Liu Guo-Zhong, Zhou Zhe-Hai, Qiu Jun, Wang Xiao-Fei, Liu Gui-Li, Wang Rui-Kang
PDF
Get Citation

(PLEASE TRANSLATE TO ENGLISH

BY GOOGLE TRANSLATE IF NEEDED.)

  • The amplitude and phase fluctuations of A-scans, influenced by the galvanometer positioning accuracy, mechanical jitter, and especially the ovement of the sample, may lead to the distortion and degradation of the tissue structure images and the blood flow images within tissue beds in frequency domain optical coherence tomography. The amplitude registration method for A-scans is proposed based on the minimum intensity difference matching criterion, Lorentzian curve fitting method, and compensation of the optical path difference in interference spectrum. The phase differences between A-scans are detected and registered by matching of phase distribution characteristics of A-scans. After the amplitude and phase registration, the complex signal differences between two A-scans are calculated to eliminate the effect of the static tissue on the blood flow imaging. The eye scanning experiments were performed and three-dimensional blood flow images of retina were acquired. Experiment results indicate that the effect of system scanning accuracy and tissue movement on the image quality can be effectively eliminated by the proposed amplitude and phase registration method. The fast and accurate phase registration method can also be used in Doppler OCT, phase microscope, and other phase related applications.
    • Funds: Project supported by the National Natural Science Foundation of China (Grant Nos. 61240057, 61108047), and the National Institute of Health (NIH) of USA (Grant Nos. R01HL093140, R01HL093140S).
    [1]

    Shang Z M, Ding Z H, Wang L, Liu Y 2011 Acta Phys. Sin. 60 21404 (in Chinese) [商在明, 丁志华, 王玲, 刘勇 2011 60 21404]

    [2]

    Shen T M, Gu Y 2007 Chin. J Laser Med. Surg. 16 379 (in Chinese) [沈婷梅, 顾瑛 2007 中国激光医学杂志 16 379]

    [3]

    Kim D Y, Fingler J, Werner J S, Schwartz D M, Fraser S E, Zawadzki R J 2011 Biomed. Opt. Express 2 1504

    [4]

    Kwiterovich K A, Maguire M G, Murphy R P 1991 Ophthalmology 98 1139

    [5]

    Wang X J, Milner T E, Nelson J S 1995 Opt. Lett. 20 1337

    [6]

    Chen Z, Milner T E, Dave D, Nelson J S 1997 Opt. Lett. 22 64

    [7]

    Meng J, Ding Z H, Zhu Y 2009 Acta Optica Sinica 29 3168 (in Chinese) [孟婕, 丁志华, 朱瑛 2009 光学学报 29 3168]

    [8]

    White B R, Pierce M C, Nassif N, Cense B, Park B H, Tearney G J, Bouma B E, Chen T C, Boer J F 2003 Opt. Express 11 3490

    [9]

    Leitgeb R, Schmetterer L, Drexler W, Fercher A, Zawadzki R, Bajraszewski T 2003 Opt. Express 11 3116

    [10]

    Zotter S, Pircher M, Torzicky T, Bonesi M, Götzinger E, Leitgeb R A, Hitzenberger C K 2011 Opt. Express 19 1217

    [11]

    Makita S, Jaillon F, Yamanari M, Miura M, Yasuno Y 2011 Opt. Express 19 1271

    [12]

    Fingler J, Schwartz D, Yang C H, Fraser S E 2007 Opt. Express 15 12636

    [13]

    Mariampillai A, Standish B A, Moriyama E H, Khurana M, Munce N R, Leung M K, Jiang J, Cable A, Wilson B C, Vitkin I A, Yang V X 2008 Opt. Lett. 33 1530

    [14]

    Makita S, Hong Y, Yamanari M 2006 Opt. Express 14 7821

    [15]

    Wang R K, Hurst S 2007 Opt. Express 15 11402

    [16]

    An L, Qin J, Wang R K 2010 Opt. Express 18 8220

    [17]

    Szkulmowski M, Szkulmowska A, Bajraszewski T, Kowalczyk A, Wojtkowski M 2008 Opt. Express 16 6008

    [18]

    Huang L M, Ding Z H, Hong W, Wang C 2012 Acta Phys. Sin. 61 023401 (in Chinese) [黄良敏, 丁志华, 洪威, 王川 2012 61 023401]

    [19]

    Bachmann A H, Villiger M L, Blatter C, Lasser T, Leitgeb R A 2007 Opt. Express 15 408

    [20]

    Ferguson R D, Hammer D X, Paunescu L A, Beaton S, Schuman J S 2004 Opt. Lett. 29 2139

    [21]

    Kinkelder R D, Kalkman J, Faber D 2011 Invest. Ophthalmol. Vis. Sci. 52 3908

    [22]

    Joo C, Akkin T, Cense B, Park B H, de Boer J F 2005 Opt. Lett. 30 2131

    [23]

    Lin D, Jiang X, Xie F, Zhang W, Zhang L, Bennion I 2004 Opt. Express 12 5729

    [24]

    Yaqoob Z, Choi W, Oh S, Niyom L, Park Y, Fang Y C, Dasari R R, Badizadegan K, Feld M S 2009 Opt. Express 17 10681

    [25]

    Tomlins P H, Wang R K 2007 Meas. Sci. Technol. 18 3365

    [26]

    Yang C, Wax A, Hahn M S, Badizadegan K, Dasari R R, Feld M S 2001 Opt. Lett. 26 1271

    [27]

    Ralston T S, Marks D L, Carney P S, Boppart S A 2006 3rd IEEE International Symposium on Biomedical Imaging: Nano to Macro April 6-9, 2006 p578

    [28]

    Yu L F, Rao B, Zhang J, Su J P, Wang Q, Guo S G, Chen Z P 2007 Opt. Express 15 7634

    [29]

    Vakoc B J, Yun S H, de Boer J F, Tearney G J, Bouma B E 2005 Opt. Express 13 5483

    [30]

    An L, Wang R K 2008 Opt. Express 16 11438

    [31]

    Braaf B, Vermeer K A, Vienola K V, de Boer J F 2012 Opt. Express 20 20516

    [32]

    Liu G Z, Wang R K 2013 Chin. Opt. Lett. 11 031701

  • [1]

    Shang Z M, Ding Z H, Wang L, Liu Y 2011 Acta Phys. Sin. 60 21404 (in Chinese) [商在明, 丁志华, 王玲, 刘勇 2011 60 21404]

    [2]

    Shen T M, Gu Y 2007 Chin. J Laser Med. Surg. 16 379 (in Chinese) [沈婷梅, 顾瑛 2007 中国激光医学杂志 16 379]

    [3]

    Kim D Y, Fingler J, Werner J S, Schwartz D M, Fraser S E, Zawadzki R J 2011 Biomed. Opt. Express 2 1504

    [4]

    Kwiterovich K A, Maguire M G, Murphy R P 1991 Ophthalmology 98 1139

    [5]

    Wang X J, Milner T E, Nelson J S 1995 Opt. Lett. 20 1337

    [6]

    Chen Z, Milner T E, Dave D, Nelson J S 1997 Opt. Lett. 22 64

    [7]

    Meng J, Ding Z H, Zhu Y 2009 Acta Optica Sinica 29 3168 (in Chinese) [孟婕, 丁志华, 朱瑛 2009 光学学报 29 3168]

    [8]

    White B R, Pierce M C, Nassif N, Cense B, Park B H, Tearney G J, Bouma B E, Chen T C, Boer J F 2003 Opt. Express 11 3490

    [9]

    Leitgeb R, Schmetterer L, Drexler W, Fercher A, Zawadzki R, Bajraszewski T 2003 Opt. Express 11 3116

    [10]

    Zotter S, Pircher M, Torzicky T, Bonesi M, Götzinger E, Leitgeb R A, Hitzenberger C K 2011 Opt. Express 19 1217

    [11]

    Makita S, Jaillon F, Yamanari M, Miura M, Yasuno Y 2011 Opt. Express 19 1271

    [12]

    Fingler J, Schwartz D, Yang C H, Fraser S E 2007 Opt. Express 15 12636

    [13]

    Mariampillai A, Standish B A, Moriyama E H, Khurana M, Munce N R, Leung M K, Jiang J, Cable A, Wilson B C, Vitkin I A, Yang V X 2008 Opt. Lett. 33 1530

    [14]

    Makita S, Hong Y, Yamanari M 2006 Opt. Express 14 7821

    [15]

    Wang R K, Hurst S 2007 Opt. Express 15 11402

    [16]

    An L, Qin J, Wang R K 2010 Opt. Express 18 8220

    [17]

    Szkulmowski M, Szkulmowska A, Bajraszewski T, Kowalczyk A, Wojtkowski M 2008 Opt. Express 16 6008

    [18]

    Huang L M, Ding Z H, Hong W, Wang C 2012 Acta Phys. Sin. 61 023401 (in Chinese) [黄良敏, 丁志华, 洪威, 王川 2012 61 023401]

    [19]

    Bachmann A H, Villiger M L, Blatter C, Lasser T, Leitgeb R A 2007 Opt. Express 15 408

    [20]

    Ferguson R D, Hammer D X, Paunescu L A, Beaton S, Schuman J S 2004 Opt. Lett. 29 2139

    [21]

    Kinkelder R D, Kalkman J, Faber D 2011 Invest. Ophthalmol. Vis. Sci. 52 3908

    [22]

    Joo C, Akkin T, Cense B, Park B H, de Boer J F 2005 Opt. Lett. 30 2131

    [23]

    Lin D, Jiang X, Xie F, Zhang W, Zhang L, Bennion I 2004 Opt. Express 12 5729

    [24]

    Yaqoob Z, Choi W, Oh S, Niyom L, Park Y, Fang Y C, Dasari R R, Badizadegan K, Feld M S 2009 Opt. Express 17 10681

    [25]

    Tomlins P H, Wang R K 2007 Meas. Sci. Technol. 18 3365

    [26]

    Yang C, Wax A, Hahn M S, Badizadegan K, Dasari R R, Feld M S 2001 Opt. Lett. 26 1271

    [27]

    Ralston T S, Marks D L, Carney P S, Boppart S A 2006 3rd IEEE International Symposium on Biomedical Imaging: Nano to Macro April 6-9, 2006 p578

    [28]

    Yu L F, Rao B, Zhang J, Su J P, Wang Q, Guo S G, Chen Z P 2007 Opt. Express 15 7634

    [29]

    Vakoc B J, Yun S H, de Boer J F, Tearney G J, Bouma B E 2005 Opt. Express 13 5483

    [30]

    An L, Wang R K 2008 Opt. Express 16 11438

    [31]

    Braaf B, Vermeer K A, Vienola K V, de Boer J F 2012 Opt. Express 20 20516

    [32]

    Liu G Z, Wang R K 2013 Chin. Opt. Lett. 11 031701

  • [1] Fu Ya-Peng, Sun Qian-Dong, Li Bo-Yi, Ta De-An, Xu Kai-Liang. Three-dimensional ultrafast ultrasound imaging of blood flow using row-column addressing array: A simulation study. Acta Physica Sinica, 2023, 72(7): 074302. doi: 10.7498/aps.72.20222106
    [2] Wang Kang-Yu, Zhou Yu-Lin, He Li-Yuan, Lu Chun-Yao, Yu Run, Wu Da-Wei. Blood flow image by multi-angle composite ultrasonic Doppler vector. Acta Physica Sinica, 2022, 71(10): 104303. doi: 10.7498/aps.71.20211825
    [3] Qian Huang-He, Wang Di, Han Tao, Ding Zhi-Hua. A method of fast locating discrete interface based on phase information of complex master-slave optical coherence tomography. Acta Physica Sinica, 2022, 71(21): 214202. doi: 10.7498/aps.71.20220444
    [4] Su Bo, Tao Fen, Li Ke, Du Guo-Hao, Zhang Ling, Li Zhong-Liang, Deng Biao, Xie Hong-Lan, Xiao Ti-Qiao. Image alignment for synchrotron radiation based X-ray nano-CT. Acta Physica Sinica, 2021, 70(16): 160704. doi: 10.7498/aps.70.20210156
    [5] Wu Tong, Huo Wen-Qi, Huang Yun-Zhi, Wang Ji-Ming, Gu Xiao-Rong, Lu Yuan-Gang, He Chong-Jun, Liu You-Wen. A miniaturized pre-calibration based Lissajous scanning fiber probe for endoscopic optical coherence tomography. Acta Physica Sinica, 2021, 70(15): 150701. doi: 10.7498/aps.70.20210151
    [6] Hu Zhe-Hao, Shangguan Zi-Wei, Qiu Jian-Rong, Yang Shan-Shan, Bao Wen, Shen Yi, Li Peng, Ding Zhi-Hua. Stimulated-emission based spectral domain optical coherence tomography for molecular contrast imaging. Acta Physica Sinica, 2018, 67(17): 174201. doi: 10.7498/aps.67.20171738
    [7] Wu Tong, Sun Shuai-Shuai, Wang Xu-Hui, Wang Ji-Ming, He Chong-Jun, Gu Xiao-Rong, Liu You-Wen. Optimized linear wavenumber spectrometer based spectral-domain optical coherence tomography system. Acta Physica Sinica, 2018, 67(10): 104208. doi: 10.7498/aps.67.20172606
    [8] Fan Jin-Yu, Gao Feng, Kong Wen, Li Hai-Wen, Shi Guo-Hua. A full spectrum resamping method in polygon tunable laser-based swept-source optical coherence tomography. Acta Physica Sinica, 2017, 66(11): 114204. doi: 10.7498/aps.66.114204
    [9] Wang Yi, Guo Zhe, Zhu Li-Da, Zhou Hong-Xian, Ma Zhen-He. Nanoscale surface topography imaging using phase-resolved spectral domain optical coherence tomography. Acta Physica Sinica, 2017, 66(15): 154202. doi: 10.7498/aps.66.154202
    [10] Ma Zhen-He, Dou Shi-Dan, Ma Yu-Shu, Liu Jian, Zhao Yu-Qian, Liu Jiang-Hong, Lü Jiang-Tao, Wang Yi. Measurement of wall strain in embryonic chick heart by spectral domain optical coherence tomography. Acta Physica Sinica, 2016, 65(23): 235202. doi: 10.7498/aps.65.235202
    [11] Shangguan Zi-Wei, Shen Yi, Li Peng, Ding Zhi-Hua. Wavenumber calibration and phase measurement in swept source optical coherence tomography. Acta Physica Sinica, 2016, 65(3): 034201. doi: 10.7498/aps.65.034201
    [12] Pan Cong, Guo Li, Shen Yi, Yan Xue-Guo, Ding Zhi-Hua, Li Peng. Phase correction method based on interfacial signal in swept source optical coherence tomography. Acta Physica Sinica, 2016, 65(1): 014201. doi: 10.7498/aps.65.014201
    [13] Tang Tao, Zhao Chen, Chen Zhi-Yan, Li Peng, Ding Zhi-Hua. Ultrahigh-resolution optical coherence tomography and its application in inspection of industrial materials. Acta Physica Sinica, 2015, 64(17): 174201. doi: 10.7498/aps.64.174201
    [14] Zhao Liao-Ying, Lü Bu-Yun, Li Xiao-Run, Chen Shu-Han. Multi-source remote sensing image registration based on scale-invariant feature transform and optimization of regional mutual information. Acta Physica Sinica, 2015, 64(12): 124204. doi: 10.7498/aps.64.124204
    [15] Zhao Chen, Chen Zhi-Yan, Ding Zhi-Hua, Li Peng, Shen Yi, Ni Yang. Line-field parallel spectral domain optical coherence tomography and its application in defect inspection. Acta Physica Sinica, 2014, 63(19): 194201. doi: 10.7498/aps.63.194201
    [16] Ye Min, Qian Zhong-Hua, Wu Yong-Ping. Spatiotemporal evolution of the droughts and floods over China. Acta Physica Sinica, 2013, 62(13): 139203. doi: 10.7498/aps.62.139203
    [17] Bao Wen, Ding Zhi-Hua, Wang Chuan, Mei Sheng-Tao. Phase sensitive spectral domain optical coherence tomography for latent fingerprint detection. Acta Physica Sinica, 2013, 62(11): 114202. doi: 10.7498/aps.62.114202
    [18] Huang Liang-Min, Ding Zhi-Hua, Hong Wei, Wang Chuan. Correlated Doppler optical coherence tomography. Acta Physica Sinica, 2012, 61(2): 023401. doi: 10.7498/aps.61.023401
    [19] Yang Ya-Liang, Ding Zhi-Hua, Wang Kai, Wu Ling, Wu Lan. Development of full-field optical coherence tomography system. Acta Physica Sinica, 2009, 58(3): 1773-1778. doi: 10.7498/aps.58.1773
    [20] XIANG JI-YING, WU ZHEN, ZENG SHAO-QUN, LUO QING-MING, ZHANG PING, HUANG DE-XIU. ANALYSIS OF 3D TRANSFER FUNCTIONS OF OPTICAL COHERENCE TOMOGRAPHY. Acta Physica Sinica, 1999, 48(10): 1831-1838. doi: 10.7498/aps.48.1831
Metrics
  • Abstract views:  5608
  • PDF Downloads:  807
  • Cited By: 0
Publishing process
  • Received Date:  09 January 2013
  • Accepted Date:  29 March 2013
  • Published Online:  05 August 2013

/

返回文章
返回