In the study of the gas detectors, it is an important calibration method to use the ultraviolet (UV) laser with two-photon ionization mechanism for producing ionized signal. In the last decades, micro pattern gas detector, especially gaseous electron multiplier and micromesh gaseous detector, has been widely used in high energy experiments. These kinds of gaseous detectors have the advantages of higher ion backflow suppression ability, smaller E × B effect and good radiation resistance under the relatively higher count rate environment. To obtain a higher spatial resolution with a UV laser calibration system in gaseous electron multiplier detector, two critical technical issues remain to be resolved: the measurability of the laser signal and the accuracy of the laser beam position. In this paper, the studies in simulation and experiment are conducted to discuss these two critical questions. In the simulation section, the simulation results provide an estimation of signal in the gaseous electron multiplier detector with UV laser of 266 nm wavelength in the mixture working gases of Ar/CO2 (70/30), and give an evaluation of the laser pointing accuracy and the possible relative error of the electron drift velocity. In the experiment section, a UV laser calibration prototype is designed and developed. A pulsed laser of 266 nm wavelength is used as a signal source, which has a Gaussian-like cross section with a frequency of 10 Hz. The experimental results indicate that the signal of the UV laser in a triple gaseous electron multiplier detector reaches 400 mV for a readout strip width of 6 mm, a gain of detector of 5000, and a gain of amplifier of 10 mV/fC. For the calibration laser, the angle accuracy is discussed and tested. The angle uncertainty of the laser can be kept under 5′, and the accuracy of the drift velocity can reach 6.4 × 10−4 with a shift of 0.33 mm in the z direction when the laser beam transmits a distance of 400 mm in the gas chamber. All of these results show that the laser beam specific parameters are the main reference for designing the prototype detector. According to the optimal parameters, a gaseous prototype detector will be tested in the next study.
[1] Leonard A 2015 Ph. D. Dissertation (Bruxelles: Université Libre de Bruxelles)
[2] Delbart A, de Oliveira R, Derre J, Giomataris Y, Jeanneau F, Papadopoulos Y, Rebourgeard Ph 2001 Nucl. Instrum. Methods A 461 84Google Scholar
[3] Zibell A 2014 J. Instrum. 9 C08013Google Scholar
[4] Sauli F 2002 Nucl. Instrum. Methods A 477 1Google Scholar
[5] Sauli F 1997 Nucl. Instrum. Methods A 386 531Google Scholar
[6] Chernyshova M, Czarski T, Dominik W, Jakubowska K, Rzadkiewicz J, Scholz M, Pozniak K, Kasprowicz G, Zabolotny W 2014 J. Instrum. 9 C03003Google Scholar
[7] Giomataris I, Oliveira R D, Andriamonje S, Aune S, Charpak G, Colas P, Fanourakis G, Ferrer E, Giganon A, Rebourgeard Ph, Salin P 2006 Nucl. Instrum. Methods A 560 405Google Scholar
[8] Giomataris, Y 1998 Nucl. Instrum. Methods A 419 239Google Scholar
[9] Colas P, Giomataris I, Lepeltier V 2004 Nucl. Instrum. Methods A 535 226Google Scholar
[10] The LHCb collaboration 2015 Int. J. Mod. Phys. A 30 1530022Google Scholar
[11] Balla A, Bencivenni G, Branchini P, Ciambrone P, Czerwinski E, de Lucia E, Cicco A, Di Domenici D, Felici G, Morello G 2017 Nucl. Instrum. Methods A 845 266Google Scholar
[12] Dørheim S 2012 J. Instrum. 7 C03011
[13] Adinoff B, Kramer G L, Petty F 2007 Nucl. Instrum. Methods A 577 455Google Scholar
[14] Ketzer B, Weitzel Q, Paul S, Sauli F, Ropelewski L 2004 Nucl. Instrum. Methods A 535 314Google Scholar
[15] Hilke H J 2010 Rep. Prog. Phys. 73 116201Google Scholar
[16] Attie D 2009 Nucl. Instrum. Methods A 598 89Google Scholar
[17] Kane S, May J, Miyamoto J, Shipsey I 2003 Nucl. Instrum. Methods A 505 215Google Scholar
[18] Hilke H J 1986 Nucl. Instrum. Methods A 252 169Google Scholar
[19] Renault G, Nielsen B S, Westergaard J, Gaardhoje J J 2005 Czech. J. Phys. 55 1671Google Scholar
[20] Antończyk D, Baechler J, Bramm R, Campagnolo R, Christiansen P, Frankenfeld U, Gonzalez Gutierrez C, Ivanov M, Kowalski M, Musa L, Przybyla A 2006 Nucl. Instrum. Methods A 565 551Google Scholar
[21] Wikipedia https://en.wikipedia.org/wiki/Gaussian_beam [2018-08-30]
[22] 祁金刚, 李春杰 2007 物理实验 27 34Google Scholar
Qi J G, Li C J 2007 Physics Experimentation 27 34Google Scholar
[23] 王小胡, 王守印, 周虎, 张余彬 2006 仪器仪表学报 27 980Google Scholar
Wang X H, Wang S Y, Zhou H, Zhang Y B 2006 Chinese Journal of Scientific Instrument 27 980Google Scholar
-
-
[1] Leonard A 2015 Ph. D. Dissertation (Bruxelles: Université Libre de Bruxelles)
[2] Delbart A, de Oliveira R, Derre J, Giomataris Y, Jeanneau F, Papadopoulos Y, Rebourgeard Ph 2001 Nucl. Instrum. Methods A 461 84Google Scholar
[3] Zibell A 2014 J. Instrum. 9 C08013Google Scholar
[4] Sauli F 2002 Nucl. Instrum. Methods A 477 1Google Scholar
[5] Sauli F 1997 Nucl. Instrum. Methods A 386 531Google Scholar
[6] Chernyshova M, Czarski T, Dominik W, Jakubowska K, Rzadkiewicz J, Scholz M, Pozniak K, Kasprowicz G, Zabolotny W 2014 J. Instrum. 9 C03003Google Scholar
[7] Giomataris I, Oliveira R D, Andriamonje S, Aune S, Charpak G, Colas P, Fanourakis G, Ferrer E, Giganon A, Rebourgeard Ph, Salin P 2006 Nucl. Instrum. Methods A 560 405Google Scholar
[8] Giomataris, Y 1998 Nucl. Instrum. Methods A 419 239Google Scholar
[9] Colas P, Giomataris I, Lepeltier V 2004 Nucl. Instrum. Methods A 535 226Google Scholar
[10] The LHCb collaboration 2015 Int. J. Mod. Phys. A 30 1530022Google Scholar
[11] Balla A, Bencivenni G, Branchini P, Ciambrone P, Czerwinski E, de Lucia E, Cicco A, Di Domenici D, Felici G, Morello G 2017 Nucl. Instrum. Methods A 845 266Google Scholar
[12] Dørheim S 2012 J. Instrum. 7 C03011
[13] Adinoff B, Kramer G L, Petty F 2007 Nucl. Instrum. Methods A 577 455Google Scholar
[14] Ketzer B, Weitzel Q, Paul S, Sauli F, Ropelewski L 2004 Nucl. Instrum. Methods A 535 314Google Scholar
[15] Hilke H J 2010 Rep. Prog. Phys. 73 116201Google Scholar
[16] Attie D 2009 Nucl. Instrum. Methods A 598 89Google Scholar
[17] Kane S, May J, Miyamoto J, Shipsey I 2003 Nucl. Instrum. Methods A 505 215Google Scholar
[18] Hilke H J 1986 Nucl. Instrum. Methods A 252 169Google Scholar
[19] Renault G, Nielsen B S, Westergaard J, Gaardhoje J J 2005 Czech. J. Phys. 55 1671Google Scholar
[20] Antończyk D, Baechler J, Bramm R, Campagnolo R, Christiansen P, Frankenfeld U, Gonzalez Gutierrez C, Ivanov M, Kowalski M, Musa L, Przybyla A 2006 Nucl. Instrum. Methods A 565 551Google Scholar
[21] Wikipedia https://en.wikipedia.org/wiki/Gaussian_beam [2018-08-30]
[22] 祁金刚, 李春杰 2007 物理实验 27 34Google Scholar
Qi J G, Li C J 2007 Physics Experimentation 27 34Google Scholar
[23] 王小胡, 王守印, 周虎, 张余彬 2006 仪器仪表学报 27 980Google Scholar
Wang X H, Wang S Y, Zhou H, Zhang Y B 2006 Chinese Journal of Scientific Instrument 27 980Google Scholar
Catalog
Metrics
- Abstract views: 7763
- PDF Downloads: 49
- Cited By: 0