A two-dimensional multi-wire proportional chamber detector based on 3He gas is developed for meeting the multifunctional reflection spectrum detection requirements of China Spallation Neutron Source (CSNS). Based on the previous researches in our laboratory, three different wire structures are studied for optimizing the wire readout structure of the two-dimensional multi-wire proportional chamber detector, and the performances of the detectors are measured by two readout methods:the center of gravity readout method and the digital readout method in this paper. The selected method could satisfy the requirement of multifunctional reflection spectrum instrument. Finally, the results indicate that the position resolution and the imaging capability obtained by using the center of gravity readout method should be better than by using the digital readout method. The position resolution could reach to about 160 m by using the center of gravity readout method. While the position resolution of the detector could be obtained to be about 400 m by using the digital readout method. Re-designed and compared with each other are the three different wire structures:1.5 mm of the anode wire pitch and 4 mm of the readout strip pitch with the center of gravity readout method, 1.5 mm of the anode wire pitch and 2 mm of the readout strip pitch with the digital readout method. Both of the optimized designs of the wire structure could meet the requirement of the position resolution for the reflection spectrum device.
-
Keywords:
- two-dimension multi-wire proportional chamber /
- center of gravity readout method /
- digital readout method /
- position resolution
[1] Orban J, Cser L, Rosta L, Trk Gy, Nagy A 2011 NIMA 632 124
[2] Li X L, Zhang Y L, Qian H, Xu Z Z, Wang X L 2008 Chin. Phys. C 36 519
[3] Radeka V, Boie R A 1980 NuclearInstruments and Methods 178 543
[4] Fonte P 1994 NIMA 348 338
[5] Sitar B, Stubbs R J, Breare J M 1976 Nuclear Instruments and Methods 134 267
[6] Tian L C, Sun Z J, Qi H R, Tang B, L X Y, Chen Y B, Ouyang Q 2013 Nucl. Phys. Rev. 30 42
[7] Wang X H 2009 Ph. D. Dissertation (Beijing:University of Chinese Academy of Sciences) (in Chinese)[王小胡2009博士学位论文(北京:中国科学院大学)]
-
[1] Orban J, Cser L, Rosta L, Trk Gy, Nagy A 2011 NIMA 632 124
[2] Li X L, Zhang Y L, Qian H, Xu Z Z, Wang X L 2008 Chin. Phys. C 36 519
[3] Radeka V, Boie R A 1980 NuclearInstruments and Methods 178 543
[4] Fonte P 1994 NIMA 348 338
[5] Sitar B, Stubbs R J, Breare J M 1976 Nuclear Instruments and Methods 134 267
[6] Tian L C, Sun Z J, Qi H R, Tang B, L X Y, Chen Y B, Ouyang Q 2013 Nucl. Phys. Rev. 30 42
[7] Wang X H 2009 Ph. D. Dissertation (Beijing:University of Chinese Academy of Sciences) (in Chinese)[王小胡2009博士学位论文(北京:中国科学院大学)]
Catalog
Metrics
- Abstract views: 5971
- PDF Downloads: 176
- Cited By: 0