-
The advantages of the tri-axial relativistic klystron amplifier and the multi-beam klystron amplifier are analyzed, and then an X-band coaxial multi-beam relativistic klystron amplifier is designed in order to increase the output microwave power and frequency. Based on the results from partial-in-cell simulation, the experiment is performed on the Sinus accelerator. In experiment, the transmission and bunching of electron beam are analyzed, and then the amplifier is driven by a beam of 5.3 kA at 670 kV, and the maximum output power is 420 MW when input power is 30 kW, and frequency is 9.375 GHz. The experiment proves that a ten kW-level input power can drive the X-band coaxial multi-beam relativistic klystron amplifier to generate more than one hundred MW-level output power.
-
Keywords:
- high power microwave /
- relativistic klystron amplifier /
- X-band /
- coaxial multi-beam
[1] Benford J, Swegle J A 2008 High Power Microwave (2 Edn.) (Beijing: National Defense Industry Press) pp293-335 (in Chinese) [Benford J, Swegle J A 2008 高功率微波(第二版)(中译本)(北京:国防工业出版社) 第293—335页]
[2] Robert J B, Edl S 2005 High Power Microwave Sources and Technologies (Beijing: Tsinghua university Press) pp57-63 (in Chinese) [Robert J B, Edl S 2005 高功率微波源与技术(中译本) (北京:清华大学出版社) 第57—63页]
[3] Pasour J, Smithe D, Ludeking L 2003 The American Institute of Physics Conf. Proc. 691 141
[4] Ding Y G 2002 Vacuum Electronics 5 8 (in Chinese) [丁耀根 2002 真空电子技术 5 8]
[5] Zhang R, Wang Y 2007 Vacuum Electronics 3 25 (in Chinese) [张瑞, 王勇 2007 真空电子技术 3 25]
[6] Liu Z B, Huang H, Jin X, Chen H B 2011 Acta Phys. Sin. 60 128402 (in Chinese) [刘振帮, 黄华, 金晓, 陈怀璧 2011 60 128402]
[7] Ding Y G 2010 Design, Manufacture and Application of High Power Klystron (Beijing: National Defense Industry Press) pp57-60 (in Chinese) [丁耀根 2010 大功率速调管的设计制造和应用 (北京: 国防工业出版社) 第57—60页]
[8] Wu Y, Xu Z, Xu Y, Jin X 2011 011 Acta Phys. Sin. 60 044102 (in Chinese) [吴洋, 许州, 徐勇, 金晓 2011 60 044102]
[9] Liu Z B, Huang H, Jin X, Chen H B 2011 High Power Laser and Particle Beams 23 2162 (in Chinese) [刘振帮, 黄华, 金晓, 陈怀璧 2011 强激光与粒子束 23 2162]
-
[1] Benford J, Swegle J A 2008 High Power Microwave (2 Edn.) (Beijing: National Defense Industry Press) pp293-335 (in Chinese) [Benford J, Swegle J A 2008 高功率微波(第二版)(中译本)(北京:国防工业出版社) 第293—335页]
[2] Robert J B, Edl S 2005 High Power Microwave Sources and Technologies (Beijing: Tsinghua university Press) pp57-63 (in Chinese) [Robert J B, Edl S 2005 高功率微波源与技术(中译本) (北京:清华大学出版社) 第57—63页]
[3] Pasour J, Smithe D, Ludeking L 2003 The American Institute of Physics Conf. Proc. 691 141
[4] Ding Y G 2002 Vacuum Electronics 5 8 (in Chinese) [丁耀根 2002 真空电子技术 5 8]
[5] Zhang R, Wang Y 2007 Vacuum Electronics 3 25 (in Chinese) [张瑞, 王勇 2007 真空电子技术 3 25]
[6] Liu Z B, Huang H, Jin X, Chen H B 2011 Acta Phys. Sin. 60 128402 (in Chinese) [刘振帮, 黄华, 金晓, 陈怀璧 2011 60 128402]
[7] Ding Y G 2010 Design, Manufacture and Application of High Power Klystron (Beijing: National Defense Industry Press) pp57-60 (in Chinese) [丁耀根 2010 大功率速调管的设计制造和应用 (北京: 国防工业出版社) 第57—60页]
[8] Wu Y, Xu Z, Xu Y, Jin X 2011 011 Acta Phys. Sin. 60 044102 (in Chinese) [吴洋, 许州, 徐勇, 金晓 2011 60 044102]
[9] Liu Z B, Huang H, Jin X, Chen H B 2011 High Power Laser and Particle Beams 23 2162 (in Chinese) [刘振帮, 黄华, 金晓, 陈怀璧 2011 强激光与粒子束 23 2162]
Catalog
Metrics
- Abstract views: 8653
- PDF Downloads: 562
- Cited By: 0