半导体激光器的电流调谐非线性对自外差相干测量的精度影响很大.研究了分布反馈半导体(DFB)激光器的电流调谐特性,据此提出一种数学模型补偿方法.利用已知光程差下的差拍频率,建立了动态调频系数的数学模型.以此模型对DFB激光器的电流调谐非线性进行补偿,可以将差拍信号频率预测值的相对误差减小约3%,提高了系统的测量精度.数学模型补偿方法简化了测量系统的结构,适用于高精度的电流调谐激光在线测量系统.
-
关键词:
- 自外差相干测量 /
- 分布反馈半导体激光器 /
- 调谐非线性 /
- 数学模型补偿
The measuring accuracy of self-heterodyne coherent measuring system can be deteriorated by the tuning nonlinearity of the diode laser with injection current. The tuning characteristics of a DFB laser were analyzed, and a mathematical model for compensating Mach-Zehnder interferometer based self-heterodyne system was presented. The dynamic frequency modulation coefficient of the model was built by prior beat frequency of foregone optical path difference. The relative error of predicted beat frequency is reduced about 3%. This method could simplify the setup of the system, and is especially suited for online tunable laser measurement system.-
Keywords:
- self-heterodyne coherent measure /
- DFB diode laser /
- tuned nonlinearity /
- mathematical model compensate
[1] Hao X Q, Chen G X 2010 Opt. Commun. Tech. 34 4 (in Chinese)[郝秀晴, 陈根祥 2010 光通信技术 34 4]
[2] Wang M, Zhang Y J, Liu J G, LiuWQ, Kan R F,Wang T D, Chen D, Chen J Y, Wang X M, Xia H, Fang X 2006 Chin. Opt. Lett. 4 363
[3] Tarsitano C G, Webster C R 2007 Appl. Opt. 46 6923
[4] Manuel R M, Shlyagin M G, Miridonov S V 2008 Opt. Exp. 16 20666
[5] Fan X Y, Koshikiya Y, Ito F 2007 Opt. Lett. 32 3227
[6] Soller B J, Gifford D K, Wolfe M S, Froggatt M E 2005 Opt. Exp. 13 666
[7] Buus J, Markus C A, Daniel J B 2005 Tunable Laser Diodes and Related Optical Sources (New York:John Wiley & Sons)p59
[8] Cui H X, Qi R B, Chen W L, Xu K X 2008 Chin. J. Laser 35 1558 (in Chinese)[崔厚欣, 齐汝宾, 陈文亮, 徐可欣 2008 中国激光 35 1558]
[9] Koshikiya Y, Fan X Y, Ito F 2008 J. Lightwave Tech. 26 3287
[10] Boukari O, Hassine L, Bouchriha H, Ketata M 2010 Opt. Commun. 283 2214
[11] Liu JW, Du Z H, Li J Y, Qi R B, Xu K X 2011 Acta Phys. Sin 60 074213 (in Chinese)[刘景旺, 杜振辉, 李金义, 齐汝宾, 徐可欣 2011 60 074213]
[12] Du Z H, Zhai Y Q, Li J Y, Hu B 2009 Spectrosc. Spec. Anal. 29 3199
-
[1] Hao X Q, Chen G X 2010 Opt. Commun. Tech. 34 4 (in Chinese)[郝秀晴, 陈根祥 2010 光通信技术 34 4]
[2] Wang M, Zhang Y J, Liu J G, LiuWQ, Kan R F,Wang T D, Chen D, Chen J Y, Wang X M, Xia H, Fang X 2006 Chin. Opt. Lett. 4 363
[3] Tarsitano C G, Webster C R 2007 Appl. Opt. 46 6923
[4] Manuel R M, Shlyagin M G, Miridonov S V 2008 Opt. Exp. 16 20666
[5] Fan X Y, Koshikiya Y, Ito F 2007 Opt. Lett. 32 3227
[6] Soller B J, Gifford D K, Wolfe M S, Froggatt M E 2005 Opt. Exp. 13 666
[7] Buus J, Markus C A, Daniel J B 2005 Tunable Laser Diodes and Related Optical Sources (New York:John Wiley & Sons)p59
[8] Cui H X, Qi R B, Chen W L, Xu K X 2008 Chin. J. Laser 35 1558 (in Chinese)[崔厚欣, 齐汝宾, 陈文亮, 徐可欣 2008 中国激光 35 1558]
[9] Koshikiya Y, Fan X Y, Ito F 2008 J. Lightwave Tech. 26 3287
[10] Boukari O, Hassine L, Bouchriha H, Ketata M 2010 Opt. Commun. 283 2214
[11] Liu JW, Du Z H, Li J Y, Qi R B, Xu K X 2011 Acta Phys. Sin 60 074213 (in Chinese)[刘景旺, 杜振辉, 李金义, 齐汝宾, 徐可欣 2011 60 074213]
[12] Du Z H, Zhai Y Q, Li J Y, Hu B 2009 Spectrosc. Spec. Anal. 29 3199
计量
- 文章访问数: 7724
- PDF下载量: 703
- 被引次数: 0