-
Large-scale absolute distance measurement system with high accuracy plays a significant role in science and engineering applications. In many fields such as aerospace technology, large-scale manufacture, geodetic survey and civil engineering, absolute distance measurement systems with a range of up to kilometers and accuracy of better than several micrometers are generally required. Traditional laser ranging methods such as the time-of-flight method and the interferometry method are difficult to achieve both large scale and high accuracy. With the development of femtosecond optical frequency comb technology, several ranging methods with larger range and higher accuracy are developed. In the frequency domain, the optical frequency comb has a large number of stable mode lines, or the longitudinal modes, at regular intervals, which generates the inter-mode beat signal. In this study, based on the inter-mode beat of a femtosecond laser, an absolute distance measurement system using multi-wavelength interferometric method is demonstrated. It has a simple experimental setup with high accuracy but in a limited range of 2.5 m due to the 2-period of phase detection. To achieve a large-scale measurement system, the measurement range of the experimental system is extended by using the synthetic wavelength generated by tuning the repetition frequency of the laser. With a repetition frequency change of 0.2 MHz, a synthetic wavelength of up to 1.5 km is realized, thus the measurement range of the experimental setup can be extended to 0.75 km. Besides the reference and measurement path beams, a monitor path beam and two alternately opened mechanical shutters are used to measure and compensate for the phase drift due to the unbalanced drift of the electronic circuit. By using this method, the standard deviation of the phase measurement results in 30 min is 0.022 in the experiment, and the phase drift can be compensated for very well. The measurement results from the experimental system are compared with the results from a commercial heterodyne interferometer, and the comparison between results shows a precision of better than 50 m in a displacement of 1125 mm. In the experiment, the repeatability of absolute distance measurement using the range extending method is better than 3 m, thus the range of the distance measurement system can be theoretically extended up to 7.5 km. In conclusion, we demonstrate that a large-scale absolute distance measurement system using inter-mode beat of a femtosecond laser, has a range of up to 7.5 km, an accuracy of better than 50 m and a repeatability of better than 3 m. The accuracy of the experimental system can be further improved by using photodetectors with higher bandwidth so that a higher inter-mode beat and a shorter wavelength can be used.
-
Keywords:
- inter-mode beat /
- femtosecond laser /
- large-scale distance measurement
[1] Bobroff N 1993 Meas. Sci. Technol. 4 907
[2] Smullin L D, Fiocco G 1962 Nature 194 1267
[3] Qin P, Chen W, Song Y J, Hu M L, Chai L, Wang Q Y 2012 Acta Phys. Sin. 61 240601 (in Chinese) [秦鹏, 陈伟, 宋有建, 胡明列, 柴路, 王清月 2012 61 240601]
[4] Wu H Z, Cao S Y, Zhang F M, Xing S J, Qu X H 2014 Acta Phys. Sin. 63 100601 (in Chinese) [吴翰钟, 曹士英, 张福民, 邢书剑, 曲兴华 2014 63 100601]
[5] Liao S S, Yang T, Dong J J 2014 Chin. Phys. B 23 073201
[6] Zhang Y Y, Yan L L, Zhao W Y, Meng S, Fan S T, Zhang L, Guo W G, Zhang S G, Jiang H F 2015 Chin. Phys. B 24 064209
[7] Meng F, Cao S Y, Cai Y, Wang G Z, Cao J P, Li T C, Fang Z J 2011 Acta Phys. Sin. 60 100601 (in Chinese) [孟飞, 曹士英, 蔡岳, 王贵重, 曹建平, 李天初, 方占军 2011 60 100601]
[8] Minoshima K, Matsumoto H 2000 Appl. Opt. 39 5512
[9] Minoshima K, Inaba H, Matsumoto H 2007 Digest of the IEEE/LEOS Summer Topical Meetings Portland, OR, United States, July 23-25, 2007 p186
[10] Joo K N, Kim S W 2006 Opt. Express 14 5954
[11] Coddington I, Swann W C, Nenadovic L, Newbury N R 2009 Nature Photonics 3 351
[12] Wu G H, Takahashi M, Inaba H, Minoshima K 2013 Opt. Lett. 38 2140
[13] Newbury N R 2011 Nature Photonics 5 186
[14] Hua Q, Zhou W H, Xu Y 2012 Metrology { Measurement Technology 32 1 (in Chinese) [华卿, 周维虎, 许艳 2012 计测技术 32 1]
[15] Edln B 1966 Metrologia 2 71
[16] Bnsch G, Potulski E 1998 Metrologia 35 133
[17] Hochrein T, Wilk R, Mei M, Holzwarth R, Krumbholz N, Koch M 2010 Opt. Express 18 1613
[18] Doloca N R, Melners-Hagen K, Wedde M, Pollinger F, Abou-Zeid A 2010 Meas. Sci. Technol. 21 115302
-
[1] Bobroff N 1993 Meas. Sci. Technol. 4 907
[2] Smullin L D, Fiocco G 1962 Nature 194 1267
[3] Qin P, Chen W, Song Y J, Hu M L, Chai L, Wang Q Y 2012 Acta Phys. Sin. 61 240601 (in Chinese) [秦鹏, 陈伟, 宋有建, 胡明列, 柴路, 王清月 2012 61 240601]
[4] Wu H Z, Cao S Y, Zhang F M, Xing S J, Qu X H 2014 Acta Phys. Sin. 63 100601 (in Chinese) [吴翰钟, 曹士英, 张福民, 邢书剑, 曲兴华 2014 63 100601]
[5] Liao S S, Yang T, Dong J J 2014 Chin. Phys. B 23 073201
[6] Zhang Y Y, Yan L L, Zhao W Y, Meng S, Fan S T, Zhang L, Guo W G, Zhang S G, Jiang H F 2015 Chin. Phys. B 24 064209
[7] Meng F, Cao S Y, Cai Y, Wang G Z, Cao J P, Li T C, Fang Z J 2011 Acta Phys. Sin. 60 100601 (in Chinese) [孟飞, 曹士英, 蔡岳, 王贵重, 曹建平, 李天初, 方占军 2011 60 100601]
[8] Minoshima K, Matsumoto H 2000 Appl. Opt. 39 5512
[9] Minoshima K, Inaba H, Matsumoto H 2007 Digest of the IEEE/LEOS Summer Topical Meetings Portland, OR, United States, July 23-25, 2007 p186
[10] Joo K N, Kim S W 2006 Opt. Express 14 5954
[11] Coddington I, Swann W C, Nenadovic L, Newbury N R 2009 Nature Photonics 3 351
[12] Wu G H, Takahashi M, Inaba H, Minoshima K 2013 Opt. Lett. 38 2140
[13] Newbury N R 2011 Nature Photonics 5 186
[14] Hua Q, Zhou W H, Xu Y 2012 Metrology { Measurement Technology 32 1 (in Chinese) [华卿, 周维虎, 许艳 2012 计测技术 32 1]
[15] Edln B 1966 Metrologia 2 71
[16] Bnsch G, Potulski E 1998 Metrologia 35 133
[17] Hochrein T, Wilk R, Mei M, Holzwarth R, Krumbholz N, Koch M 2010 Opt. Express 18 1613
[18] Doloca N R, Melners-Hagen K, Wedde M, Pollinger F, Abou-Zeid A 2010 Meas. Sci. Technol. 21 115302
计量
- 文章访问数: 8094
- PDF下载量: 300
- 被引次数: 0