用短程飞行时间吸收谱对铯磁光阱中冷原子温度的测量

CSTR: 32037.14.aps.54.5104

Temperature measurement of cold atoms in a cesium magneto-optical trap by means of short-distance time-of-flight absorption spectrum

CSTR: 32037.14.aps.54.5104
PDF
导出引用
  • 介绍采用短程飞行时间吸收谱测量铯原子磁光阱(MOT) 中冷原子温度的基本原理及实验实现.与通常的飞行时间方法不同,采用短程飞行时间吸收谱来测量MOT 中冷原子云的温度.在MOT 区域正下方若干毫米处入射一束圆柱状共振探测光束(实验中对于h=3mm,5mm,8mm的情况均作了研究),释放冷原子云,在其膨胀和自由下落过程中穿过探测光束,即可由光电探测器测得飞行时间吸收谱,由此推得MOT中冷原子的温度.

     

    We report the basic idea and experimental demonstration of measuring the temperature of cold cesium atomic cloud confined in a magneto-optical trap (MOT) by analyzing absorption spectrum observed in the short-distance time-of-flight (TOF) method. Compared with the conventional TOF scheme, we measure the temperature of cold atomic cloud in MOT by short-distance TOF method for our small vapor cell. If the cold atomic cloud is released, it will fall and expand due to gravity and its initial velocity distribution. Utilizing a cylindrical resonant probe beam positioned several millimeters beneath the MOT (in this paper, we analyzed the cases for 3mm, 5mm, and 8mm of center-to-center distance between the MOT region and the probe beam, respectively), we can record the short-distance TOF absorption spectrum with a photodiode when cold atoms go through the probe region. Analysis of the short-distance TOF absorption spectrum yields the effective temperature of the cold cloud in MOT.

     