  • 采用每毫米1000线的自支撑透射光栅配上背照射软X射线CCD(charge coupled device)组成了透射光栅谱仪,利用北京同步辐射装置(BSRF)3W1B光束线软X射线实验站上X射线源分别对透射光栅的衍射效率和软X射线CCD的响应灵敏度进行了准确的实验标定,获得了150eV到1500eV能区的绝对衍射效率和响应灵敏度的实验结果;同时在国内外研究工作的基础上,发展了自己的透射光栅衍射效率理论计算模型和X射线CCD响应灵敏度计算模型,开展了相应的理论计算和实验标定结果比对工作,理论和实验符合较好,

     

    Transmission grating efficiencies for soft X-ray and quantum efficiencies of X-ray CCD in the energy range of 100-1500eV were carefully calibrated on Beijing Synchrotron Radiation Facility. A model is developed to simulate the calibrated grating efficiencies, another model is developed to calculate the CCD quantum efficiencies. The effect of CCD surface contamination on CCD quantum efficiency is also studied. Finally, a method for unfolding the soft X-ray spectrum measured with transmission grating spectrometer is introduced, in which the grating efficiencies, CCD quantum efficiencies and grating higher order overlapping have been taken into account. The developed quantitative measurement method has been applied to obtain X-ray spectrum from gold plasma.

     