Search

Article

x

留言板

尊敬的读者、作者、审稿人, 关于本刊的投稿、审稿、编辑和出版的任何问题, 您可以本页添加留言。我们将尽快给您答复。谢谢您的支持!

姓名
邮箱
手机号码
标题
留言内容
验证码

Design and evaluation of a pre-traveling wave deflector magnetic solenoid lens focused streak image tube

Liu Rong Tian Jin-Shou Li Hao Wang Qiang-Qiang Wang Chao Wen Wen-Long Lu Yu Liu Hu-Lin Cao Xi-Bin Wang Jun-Feng Xu Xiang-Yan Wang Xing

Citation:

Design and evaluation of a pre-traveling wave deflector magnetic solenoid lens focused streak image tube

Liu Rong, Tian Jin-Shou, Li Hao, Wang Qiang-Qiang, Wang Chao, Wen Wen-Long, Lu Yu, Liu Hu-Lin, Cao Xi-Bin, Wang Jun-Feng, Xu Xiang-Yan, Wang Xing
PDF
Get Citation

(PLEASE TRANSLATE TO ENGLISH

BY GOOGLE TRANSLATE IF NEEDED.)

  • Owing to the excellent feature of ultrahigh temporal resolution, the streak image tube has been the indispensable scientific instrument for the application to measurement of ultrafast phenomena on subpicosecond time scale. In this paper, a new femtosecond streak image tube with both high temporal and spatial resolution is designed. To improve its integrated performance, a pair of traveling wave deflectors is located before a magnetic solenoid lens in the tube, which minimizes the electron transit time from anode to deflection plates and therefore reduces time dispersion and space charge effects. Using CST microwave studio finite element method, bandwidth and deflection sensitivity of traveling wave deflector have been studied numerically. The result shows that the wide bandwidth of the traveling wave deflectors designed is beneficial to slow down the electrical deflecting pulse to match the beam velocity in a wide frequency range, which can improve the deflection sensitivity. After tracing the trajectory of electrons and calculating the modulation transform function, we get temporal resolution of 220 fs and spatial resolution above 100 lp/mm. Based on the aberration theory, the aberration formulas of electron trajectory are deduced, which systematically evaluate the imaging quality of streak image tube with modulation transfer function. Finally, static experiment is carried out, and the result shows that the static spatial resolution is better than 35 lp/mm.
    • Funds: Project supported by the National Natural Science Foundation of China (Grant Nos. 11274377, 11304374), and the Program for Major Research Instrument Development of Ministry of Finance of China (Development of High Performance Streak Cameras).
    [1]

    Bartelt A F, Comin A, Feng J, Nasiatka J R, Eimller T, Ludescher B, Schtz G, Padmore H A, Young A T, Scholl A 2007 Appl. Phys. Lett. 90 162503

    [2]

    Lindenberg A M, Kang I, Johnson S L, Missalla T, Heimann P A, Chang Z, Larsson J, Bucksbaum P H, Kapteyn H C, Padmore H A, Lee R W, Wark J S, Falcone R W 2000 Phys. Rev. Lett. 84 111

    [3]

    Johnson S L, Heimann P A, Lindenberg A M, Jeschke H O, Garcia M E, Chang Z, Lee R W, Rehr J J, Falcone R W 2003 Phys. Rev. Lett. 91 157403

    [4]

    Dong J J, Cao Z R, Yang Z H, Chen B L, Huang T X, Deng B, Liu S Y, Jiang S E, Ding Y K, Yi S Z, Mu B Z 2012 Acta Phys. Sin. 61 155208(in Chinese) [董建军, 曹柱荣, 杨正华, 陈伯伦, 黄天暄, 邓博, 刘慎业, 江少恩, 丁永坤, 伊圣振, 穆宝忠 2012 61 155208]

    [5]

    Sheng L, Wang L P, Li Y, Peng BD, Zhang M, Wu J, Wang P W, Wei F L, Yuan Y 2011 Acta Phys. Sin. 60 105205(in Chinese) [盛亮, 王亮平, 李阳, 彭博栋, 张美, 吴坚, 王培伟, 魏福利, 袁媛2011 60 105205]

    [6]

    Takahashi A, Nishizawa M, Inagaki Y, Koishi M, Kinoshita K 1994 SPIE 2116 275

    [7]

    Losovoi V, Ushkov I, Prokhorenko E, Schelev M, Smirnov A 2003 SPIE 4948 297

    [8]

    Shakya M M, Chang Z H 2005 Appl. Phys. Lett. 87 041103

    [9]

    Feng J, Engelhorn K, Cho B I, Lee H J, Greaves M, Weber C P, Falcone R W, Padmore H A, Heimann P A 2010 Appl. Phys. Lett. 96 134102

    [10]

    Tian J S, Lei X H, Wen W L, Xu X Y, Wang J F 2011 Opt. Precision Eng. 19 2379 (in Chinese) [田进寿, 雷晓红, 温文龙, 徐向晏, 王俊锋 2011 光学精密工程 19 2379]

    [11]

    Wu J X 2006 MS Thesis (LanZhou: LanZhou University)(in Chinese) [吴节险2006硕士学位论文(兰州:兰州大学)]

    [12]

    Li H, Tian J S, Li Y, Wang C, Wen W L, Wang J F, Wang X C 2013 Acta Photonica Sinica 42 792 (in Chinese) [李昊, 田进寿, 李岩, 王超, 温文龙, 王俊峰, 王兴超 2013 光子学报 42 792]

    [13]

    Tian J S, Zhao B S, Wu J J, Zhao W, Liu Y Q, Zhang J 2006 Acta Phys. Sin. 55 3368(in Chinese) [田进寿, 赵宝升, 吴建军, 赵卫, 刘运全, 张杰 2006 55 3368]

    [14]

    Liu Y P 1985 MS Thesis (Xi'an: Xi'an Institute of Optics and Presicion Mechanics of CAS)(in Chinese) [刘月平1985硕士学位论文(西安:中国科学院西安光学精密机械研究所)]

  • [1]

    Bartelt A F, Comin A, Feng J, Nasiatka J R, Eimller T, Ludescher B, Schtz G, Padmore H A, Young A T, Scholl A 2007 Appl. Phys. Lett. 90 162503

    [2]

    Lindenberg A M, Kang I, Johnson S L, Missalla T, Heimann P A, Chang Z, Larsson J, Bucksbaum P H, Kapteyn H C, Padmore H A, Lee R W, Wark J S, Falcone R W 2000 Phys. Rev. Lett. 84 111

    [3]

    Johnson S L, Heimann P A, Lindenberg A M, Jeschke H O, Garcia M E, Chang Z, Lee R W, Rehr J J, Falcone R W 2003 Phys. Rev. Lett. 91 157403

    [4]

    Dong J J, Cao Z R, Yang Z H, Chen B L, Huang T X, Deng B, Liu S Y, Jiang S E, Ding Y K, Yi S Z, Mu B Z 2012 Acta Phys. Sin. 61 155208(in Chinese) [董建军, 曹柱荣, 杨正华, 陈伯伦, 黄天暄, 邓博, 刘慎业, 江少恩, 丁永坤, 伊圣振, 穆宝忠 2012 61 155208]

    [5]

    Sheng L, Wang L P, Li Y, Peng BD, Zhang M, Wu J, Wang P W, Wei F L, Yuan Y 2011 Acta Phys. Sin. 60 105205(in Chinese) [盛亮, 王亮平, 李阳, 彭博栋, 张美, 吴坚, 王培伟, 魏福利, 袁媛2011 60 105205]

    [6]

    Takahashi A, Nishizawa M, Inagaki Y, Koishi M, Kinoshita K 1994 SPIE 2116 275

    [7]

    Losovoi V, Ushkov I, Prokhorenko E, Schelev M, Smirnov A 2003 SPIE 4948 297

    [8]

    Shakya M M, Chang Z H 2005 Appl. Phys. Lett. 87 041103

    [9]

    Feng J, Engelhorn K, Cho B I, Lee H J, Greaves M, Weber C P, Falcone R W, Padmore H A, Heimann P A 2010 Appl. Phys. Lett. 96 134102

    [10]

    Tian J S, Lei X H, Wen W L, Xu X Y, Wang J F 2011 Opt. Precision Eng. 19 2379 (in Chinese) [田进寿, 雷晓红, 温文龙, 徐向晏, 王俊锋 2011 光学精密工程 19 2379]

    [11]

    Wu J X 2006 MS Thesis (LanZhou: LanZhou University)(in Chinese) [吴节险2006硕士学位论文(兰州:兰州大学)]

    [12]

    Li H, Tian J S, Li Y, Wang C, Wen W L, Wang J F, Wang X C 2013 Acta Photonica Sinica 42 792 (in Chinese) [李昊, 田进寿, 李岩, 王超, 温文龙, 王俊峰, 王兴超 2013 光子学报 42 792]

    [13]

    Tian J S, Zhao B S, Wu J J, Zhao W, Liu Y Q, Zhang J 2006 Acta Phys. Sin. 55 3368(in Chinese) [田进寿, 赵宝升, 吴建军, 赵卫, 刘运全, 张杰 2006 55 3368]

    [14]

    Liu Y P 1985 MS Thesis (Xi'an: Xi'an Institute of Optics and Presicion Mechanics of CAS)(in Chinese) [刘月平1985硕士学位论文(西安:中国科学院西安光学精密机械研究所)]

  • [1] Tian Li-Ping, Shen Ling-bin, Chen Ping, Liu Yu-zhu, Chen Lin, Hui Dan-dan, Chen Xi-ru, Zhao Wei, Xue Yan-hua. 100 fs time-resolved streak tube design based on anisotropy and post-acceleration technology. Acta Physica Sinica, 2024, 0(0): 0-0. doi: 10.7498/aps.73.20231382
    [2] Tian Li-Ping, Shen Ling-Bin, Chen Ping, Liu Yu-Zhu, Chen Lin, Hui Dan-Dan, Chen Xi-Ru, Zhao Wei, Xue Yan-Hua, Tian Jin-Shou. 100-fs time-resolved streak tube design based on anisotropy and post-acceleration technology. Acta Physica Sinica, 2023, 72(24): 248502. doi: 10.7498/aps.72.20231382
    [3] Wang Chong, Dang Wen-Bin, Zhu Bing-Li, Yang Kai, Yang Jia-Hao, Han Jiang-Hao. Method of compensating for time measurement error of photomultiplier tube. Acta Physica Sinica, 2022, 71(22): 222901. doi: 10.7498/aps.71.20221193
    [4] Tang Yong-Hui, Zheng Zhu, Xie Shi-Meng, Huang Lin, Jiang Hua-Bei. Thermoacoustic imaging based on noise suppression of multi-channel amplifier and additive circuit. Acta Physica Sinica, 2020, 69(24): 240701. doi: 10.7498/aps.69.20201036
    [5] Gao Qiang, Li Xiao-Qiu, Zhou Zhi-Peng, Sun Lei. Far-field super-resolution scanning imaging based on fractal resonator. Acta Physica Sinica, 2019, 68(24): 244102. doi: 10.7498/aps.68.20190620
    [6] Tian Li-Ping, Li Li-Li, Wen Wen-Long, Wang Xing, Chen Ping, Lu Yu, Wang Jun-Feng, Zhao Wei, Tian Jin-Shou. Numerical calculation and experimental study on the small-size streak tube. Acta Physica Sinica, 2018, 67(18): 188501. doi: 10.7498/aps.67.20180643
    [7] Di Hui-Ge, Hua Hang-Bo, Zhang Jia-Qi, Zhang Zhan-Fei, Hua Deng-Xin, Gao Fei, Wang Li, Xin Wen-Hui, Zhao Heng. Design and analysis of high-spectral resolution lidar discriminator. Acta Physica Sinica, 2017, 66(18): 184202. doi: 10.7498/aps.66.184202
    [8] Liang Shuai-Xi, Qin Min, Duan Jun, Fang Wu, Li Ang, Xu Jin, Lu Xue, Tang Ke, Xie Pin-Hua, Liu Jian-Guo, Liu Wen-Qing. Airborne cavity enhanced absorption spectroscopy for high time resolution measurements of atmospheric NO2. Acta Physica Sinica, 2017, 66(9): 090704. doi: 10.7498/aps.66.090704
    [9] Yuan Zheng, Dong Jian-Jun, Li Jin, Chen Tao, Zhang Wen-Hai, Cao Zhu-Rong, Yang Zhi-Wen, Wang Jing, Zhao Yang, Liu Shen-Ye, Yang Jia-Min, Jiang Shao-En. Calibration of the dynamic spatial resolution of framing image-converter. Acta Physica Sinica, 2016, 65(9): 095202. doi: 10.7498/aps.65.095202
    [10] Hui Dan-Dan, Tian Jin-Shou, Lu Yu, Wang Jun-Feng, Wen Wen-Long, Liang Ling-Liang, Chen Lin. Temporal distortion analysis of the streak tube. Acta Physica Sinica, 2016, 65(15): 158502. doi: 10.7498/aps.65.158502
    [11] Chen Huo-Yao, Liu Zheng-Kun, Wang Qing-Bo, Yi Tao, Yang Guo-Hong, Hong Yi-Lin, Fu Shao-Jun. Effect of curve groove on the spectral resolution for soft X-ray holographic flat-field gratings. Acta Physica Sinica, 2014, 63(23): 234203. doi: 10.7498/aps.63.234203
    [12] Liang Mei-Yan, Zhang Cun-Lin. Improvement in the range resolution of THz radar using phase compensation algorithm. Acta Physica Sinica, 2014, 63(14): 148701. doi: 10.7498/aps.63.148701
    [13] Liang Ling-Liang, Tian Jin-Shou, Wang Tao, Li Fu-Li, Gao Gui-Long, Wang Jun-Feng, Wang Chao, Lu Yu, Xu Xiang-Yan, Cao Xi-Bin, Wen Wen-Long, Xin Li-Wei, Liu Hu-Lin, Wang Xing. Theoretical and static experiment research on all optical solid state streak camera. Acta Physica Sinica, 2014, 63(6): 060702. doi: 10.7498/aps.63.060702
    [14] Zhou Hong-Cheng, Wang Bing-Zhong, Ding Shuai, Ou Hai-Yan. Super-resolution focusing of time reversal electromagnetic waves in metal wire array medium. Acta Physica Sinica, 2013, 62(11): 114101. doi: 10.7498/aps.62.114101
    [15] Hu Hui-Jun, Zhao Bao-Sheng, Sheng Li-Zhi, Sai Xiao-Feng, Yan Qiu-Rong, Chen Bao-Mei, Wang Peng. X-ray photon counting detector for x-ray pulsar-based navigation. Acta Physica Sinica, 2012, 61(1): 019701. doi: 10.7498/aps.61.019701
    [16] Ge Guang-Ding, Wang Bing-Zhong, Huang Hai-Yan, Zheng Gang. Super-resolution characteristics of time-reversed electromagnetic wave. Acta Physica Sinica, 2009, 58(12): 8249-8253. doi: 10.7498/aps.58.8249
    [17] Zhou Xiao-Jun, Du Dong, Gong Jun-Jie. Study on spatial resolution of polarized-modes coupling distributed fiber optic sensor. Acta Physica Sinica, 2005, 54(5): 2106-2110. doi: 10.7498/aps.54.2106
    [18] Liu Li, Deng Xiao-Qiang, Wang Gui-Ying, Xu Zhi-Zhan. . Acta Physica Sinica, 2001, 50(1): 48-51. doi: 10.7498/aps.50.48
    [19] LU KUN-QUAN, CHANG LONG-CUN, ZHAO YA-QIN. THE RESOLUTION OF CRYSTAL MONOCHROMATOR FOR CONTINUOUS X-RAY SPECTRUM. Acta Physica Sinica, 1983, 32(12): 1505-1514. doi: 10.7498/aps.32.1505
    [20] LI YU. THE RELATIVISTIC ABERRATION THEORY OF A COMBINED ELECTRIC-MAGNETIC FOCUSING-DEFIECTION SYSTEM. Acta Physica Sinica, 1981, 30(9): 1155-1164. doi: 10.7498/aps.30.1155
Metrics
  • Abstract views:  6298
  • PDF Downloads:  749
  • Cited By: 0
Publishing process
  • Received Date:  03 September 2013
  • Accepted Date:  13 November 2013
  • Published Online:  05 March 2014

/

返回文章
返回
Baidu
map